VT 10 Turbine Ventilator

VT 10 Turbine Ventilator

General Features

  • Turbine based Ventilator with 1” Full Touch Screen Display
  • Wall Gas Independent System
  • Suitable for Invasive as well as Non-Invasive Ventilation
  • Suitable for Adult, Pediatric & Neonatal* Application
  • Comprehensive modes including PRVC, V+SIMV, NIV, etc
  • Upto 35 parameters monitoring
  • 360 Degree Visible alarm indicator
  • Automatic Body Weight Calculation
  • O2 Therapy
  • Extended Battery backup of upto 6 hrs*
  • Durable Expiratory Flow sensor
  • High Sensitive Respiratory Triggers (0.2s)
  • Suitable for Transport Ventilator (Foldable Screen & Carry Handle)
  • Neonatal Mode* offers a comprehensive neonatal ventilation with minimum tidal volume of 2ml

*optional (“*” Mark Symbol is for Optional Configuration)

Technical Features

Display

  • Display Size: 12.1” TFT Touch Screen
  • Display Resolution (H) x (V): 1280*800 pixels
  • Brightness: Adjustable

Power & Battery Backup

  • External AC Power Supply Input Voltage and Frequency : 100-240V and 50/60Hz
  • Number of Batteries : One or Two (optional)
  • Battery Type : Build-in-Lithium-ion Battery, 14.4VDC, 6900 mAh
  • Battery Running Time : 3 hours (1 Qty. Battery)
    6 hours (2 Qty. Battery)*

Ventilation Specifications

Invasive Ventilation Mode

  • VCV (Volume Control Ventilation)
  • PCV (Pressure Control Ventilation)
  • VSIMV (Volume Synchronized Intermittent Mandatory Ventilation)
  • PSIMV (Pressure Synchronized Intermittent Mandatory Ventilation)
  • CPAP/PSV (Continuous Positive Airway Pressure/Pressure Support Ventilation)
  • PRVC (Pressure Regulated Volume Control)
  • V+SIMV (PRVC+SIMV)
  • BPAP (Bilevel Positive Airway Pressure)
  • APRV (Airway Pressure Release Ventilation)
  • Apnea Ventilation

Non-Invasive Ventilation Mode :

  • PCV (Pressure Control Ventilation)
  • CPAP/PSV (Continuous Positive Airway Pressure/Pressure  Support Ventilation)
  • BPAP (Bilevel Positive Airway Pressure)
  • APRV (Airway Pressure Release Ventilation)
  • PSIMV (Pressure Synchronized Intermittent Mandatory Ventilation)

Physical Specifications

  • Dimensions (L*W*H): 336mm*330mm*345mm
  • Weight: Approx. 9.9kg (main unit), approx. 29.5kg (with trolley)

Controlled Parameters

Specifications Adult, Pediatric Neonatal*
O2 % 21-100% 21-100%
VT (Tidal Volume) 100-2000mL (Adult)

20-300mL (Pediatric)

2-300mL
f 1-80bpm 1-150bpm
f-SIMV 1-80bpm 1-150bpm
I:E 1:10 – 4:1 1:10 – 4:1
T-insp. 0.2-10s 0.20-10s
T-slope 0-2s 0-2s
T-high 0.2-30s 0.2-3s
T-low 0.2-30s 0.2-30s
T-pause 5%-60%, Off 5%-60%, Off
ΔP-insp. 5-80cmH2O 3-80cmH2O
ΔP-supp. 0-80cmH2O 0-80cmH2O
P-high 0-80cmH2O 0-80cmH2O
P-low 0-45cmH2O 0-25cmH2O
PEEP 1-45cmH2O, Off 1-25cmH2O, Off
Flow Trigger 0.5-15L/min 0.1-5L/min
Pressure Trigger -10-(-0.5)cmH2O /
Exp% 10-85&, Auto 10-85%, Auto

Apnea Ventilation

Specifications 
VT-apnea Adult: 100-2000mL
Pediatric: 20-300mL
Neonatal: 2-300mL
∆P-apnea 5-60cmH2O
f-apnea 1-80bpm
Apnea T-insp. 0.2-10s

Sigh

Specifications 
Sigh switch On, Off
Interval 20s-180min
Cycles Sigh 1-20
∆ int. PEEP 0-45 cmH2O, Off

Synchronized Tube Resistance Compliance

Specifications
Tube Type ET Tube, Trach. Tube, Disable STRC
Tube I.D. Adult: 5.0-12.0mm
Pediatric: 2.5-8.0mm
Compensate 0-100%
Expiration Compensation Switch On, Off

Monitored Patameters

Numeric
Paw MV-leak FiO2 C-stat.
P-peak MV-spn. f-total RC-exp.
P-plat. Vte I:E WOB
P-mean VTi Re RSBI
PEEP VTe-spn. Ri Cont. flow (O2 Therapy)
MV VTe/IBW C-dyn.

Real-Time Graphics

Pressure-time Waveform Pressure-volume loop
Flow-time Waveform Flow-time loop
Volume-time Waveform Pressure-flow loop

Trend & Record

Specifications
Type Tabular, Graphic
Length 72 Hours
Content Monitored Parameters
Max Log 20000
Screen Capture 500

Alarm Settings

Specifications Type Adult Pediatric Neonatal
Tidal Volume High
Low
110-4000mL, Off
50-4000ml, Off
25-600mL, Off
10-600mL, Off
4-600mL, Off
1-590mL, Off
Minute Volume High
Low
0.2-100.0L/min
0.1-50.0L/min
0.2-60.0L/min
0.1-30.0L/min
0.12-50.0L/min
0.02-30.0L/min
Airway Pressure High
Low
10-60cmH2O
10-63cmH2O, Off
10-60cmH2O
10-63cmH2O, Off
10-60cmH2O
10-63cmH2O, Off
Frequency High
Low
1-90bpm, Off
1-88bpm, Off
1-90bpm, Off
1-88bpm, Off
1-160bpm, Off
1-158bpm, Off
O2 Concentration High
Low
20-100%
18-98%
20-100%
18-98%
20-100%
18-98%
Apnea Alarm Time Low 5-60s 5-60s 5-60s

O2 Therapy

Specifications O2% Flow
Controlled Parameters 21-100% (Increments of 1%) 4-60L/min
Controlled Accuracy ± (3vol.% +1% of setting) ± (2L/min+10% of setting) (BTPS)

Environmental Specifications

Specifications Operating Storage and Transport
Temperature 5-40 ºC -20 – 60 ºC, O2 Sensor: -20 – 50 ºC
Relative Humidity 10-95% 10-95%
Barometric Pressure 62-106kPa 50-106kPa

Gas Supply

Specifications
Gas Supply Medical-grade Oxygen
Pipe Connector NIST or DISS
Gas Supply Pressure 280-600 kPa

Communication Interface

Specifications
Communication Interface HDMI, RS232, USB,  Nurse Call, CO2 Module Connector, Sp O2 Module Connector

Value Added Functions

  • 100% O2
  • Suction
  • Nebulization

Optional

  • Neonatal Mode
  • Extended Battery Backup
  • Supporting Arm for Breathing Circuit
  • Humidifier

Accessories

  • Trolley
  • Supporting Arm for Breathing Circuit
  • Breathing Circuit (Adult/Pediatric, Disposable, Dual Limb)
  • Flow Sensor with Tubing (Adult, Pediatric)
  • Exhalation Valve
  • Bacteria Filter
  • O2 Cell & O2 Hose (NIST/DISS)
  • Lithium Battery
  • Power Cord
  • Test Lung